Virginia Journeyman Plumber Exam Exam Prep
Free practice questions

Free VA-JP Practice Questions

10 exam-style questions with answers and explanations, straight from our 1,030-question bank. Tap an answer to check yourself. When you're ready, take the scored version in the free practice test.

Start the free practice test → ★★★★★4.9/5 from 2,400+ candidates · No signup

The VA-JP exam has 80 questions and runs 3 hours 30 minutes.

These 10 free VA-JP questions are organized by exam domain, so you can see how each part of the Virginia Journeyman Plumber Exam blueprint is tested. Reveal the answer and explanation under each question.

Domain 1: Standards of Practice

Question 1

A Virginia journeyman plumber moves to a new residence and wants Board mail sent to a post office box. Which action keeps the license record compliant?

Show answer & explanation

Correct answer: B - Notify the Board in writing within 30 days and include a physical address

Domain 2: Standards of Conduct

Question 2

After licensure, a Virginia journeyman plumber is convicted of misdemeanor theft, and the appeal period has elapsed. What does the regulation require?

Show answer & explanation

Correct answer: D - Notify the Board in writing within 30 days

Domain 3: Renewal and Reinstatement

Question 3

A plumber's license expired 18 months ago. The plumber completed the required three hours of approved code-update education and has not performed regulated work since expiration. The proper path back to active status is to:

Show answer & explanation

Correct answer: A - Apply for reinstatement and remain out of regulated work until the license is active

Domain 4: Definitions

Question 4

A tradesman can install, repair, and maintain plumbing in compliance with the Virginia Uniform Statewide Building Code and according to plans and specifications, but the facts do not establish master-level planning, layout, or supervision. Which credential level is described?

Show answer & explanation

Correct answer: C - Journeyman plumber

Domain 5: Qualification for Licensure

Question 5

Each applicant below is at least 18 years old, and all stated training and experience have been accepted as plumbing-related. Who meets a current journeyman-plumber examination-approval route?

Show answer & explanation

Correct answer: B - Seven years of practical experience plus 40 hours of formal vocational training

Domain 6: Revocation of Licensure

Question 6

The Board finds that a licensee knowingly allowed an unlicensed person to use the license and also furnished materially false information during renewal. Which range of sanctions is legally available to the Board?

Show answer & explanation

Correct answer: D - Remedial education, a monetary penalty, suspension, revocation, or refusal to renew

Domain 7: Drainage Waste and Vents

Question 7

A 3-inch horizontal building drain must run 72 feet between fixed points. The surveyed elevations provide 8 inches of fall. What is the minimum change needed to meet the required 1/8-inch-per-foot slope?

Show answer & explanation

Correct answer: A - Lower the downstream invert 1 inch, providing 9 inches of total fall

Question 8

During rough-in, a 2-inch horizontal fixture branch enters a 3-inch horizontal drain through a sanitary tee laid on its back. The fitting should be changed to a:

Show answer & explanation

Correct answer: C - Wye or combination wye and one-eighth bend aligned with flow

Question 9

For a 4-inch stack serving more than three branch intervals, the applicable limits are 500 DFU total and 90 DFU in any one branch interval. A proposed stack carries 480 DFU total, with 95 DFU entering at one interval. How should the layout be evaluated?

Show answer & explanation

Correct answer: B - Noncompliant, because the 95-DFU interval exceeds the 90-DFU limit

Question 10

A 2-inch trap arm runs 7 feet to its vent and drops 2.5 inches before the vent connection. The maximum developed length is 8 feet, and the trap arm may not fall more than one pipe diameter before venting. What makes this arrangement noncompliant?

Show answer & explanation

Correct answer: D - The 2.5-inch fall exceeds one 2-inch pipe diameter

The rest of the VA-JP blueprint

The VA-JP exam also covers these domains. Drill them in the full free practice test:

That's 10 of 1,030

The full bank has 1,020 more VA-JP questions with explanations.

Continue in the free practice test →

View plans